GoodWE SMT 4-16KW Grid-Tied inverter

PKR 465,000.00

3 MPPT – 3 Phase Goodwe SMT Series on-Grid Inverter

Description

 The brand new GoodWe SMT series inverter is ideal for medium and large-scale commercial rooftop installations, providing a maximum efficiency of 98.8 percent and up to three MPPT routes for a particular environment.With its weight of just 40 kg and compact design, the SMT series is easier to handle and install than similar inverters in the market. Featuring a maximum DC input voltage of 1100 V, wider MPPT range, and a start-up voltage of 180 V, the SMT series guarantees an earlier generation of power and a longer working time in order to maximize long-term returns and profitability for the system owner.

 

point.pngTechnical   Data GW30K-MT GW36K-MT
     
point.pngDC Input Data
     
Max. DC Input Power (W) 39000 42900
Max. DC Input Voltage (V) 1100 1100
MPPT Voltage Range (V) 200~950 200~950
Start-up Voltage (V) 180 180
MPPT Range for Full Load (V) 470~860 510~850
Nominal DC Input Voltage (V) 600 600
Max. Input Current (A) 25/25/25 25/25/25
Max. Short Current (A) 31.3/31.3/31.3 31.3/31.3/31.3
No. of MPP Trackers 3 3
No. of Input Strings per   Tracker 2/2/2 2/2/2
     
point.pngAC Output Data
     
Nominal Output Power (W) 30000 33000
Max. Output Apparent Power   (VA) 33000*1 36000
Max. Output Power (W) 33000*1 36000
Nominal Output Voltage (V) 400, 3L/N/PE or3L/PE
Nominal Output Frequency (Hz) 50/60 50/60
Max. Output Current (A) 48 53.3
Output Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDi (@Nominal Output <3% <3%
     
point.pngEfficiency
     
Max. Efficiency 98.8% 98.8%
Euro Efficiency 98.5% 98.5%
MPPT Efficiency 99.9% 99.9%
     
point.pngProtection
     
Anti-islanding Protection Integrated Integrated
Input Reverse Polarity Protection Integrated Integrated
PV String Current Monitoring Integrated Integrated
Anti-PID Function for Module Integrated Integrated
Insulation monitoring Integrated Integrated
PV Module Anti-PID
DC SPD Protectioin Optional (Type II) Optional (Type II)
AC SPD Protectioin Optional (Type II) Optional (Type II)
Residual Current Monitoring Unit Integrated Integrated
AC Over Current Protection Integrated Integrated
AC Short Protection Integrated Integrated
AC Over Voltage Protection Integrated Integrated
     
point.pngGeneral Data
     
Ambient Temperature Range (°C) -30~60 -30~60
Relative Humidity 0~100% 0~100%
Operating Altitude (m 4000 4000
Cooling Fan Cooling Fan Cooling
Noise (dB) 45 45
Display LCD & LED or LED + WiFi APP LCD & LED or LED + WiFi APP
Communication RS485 or WiFi or GPRS or PLC(with screen); WiFi+RS485or WiFi+GPRS(without screen)
Weight (kg) 40 40
Dimension (Width*Height*Depth mm) 480*590*200 480*590*200
Protection Degree IP65 IP65
Night Self Consumption (W) <1 <1
Topology Transformerless Transformerless
     
point.pngCertifications & Standards
     
Grid Regulation AS4777.2/VDE0126-1-1/VDE-AR-N 4105
Safety Regulation IEC62109-1&2
EMC Regulation EN 61000-6-1/EN 61000-6-2/EN 61000-6-3,/EN 61000-6-4
     

*1: 30000 under AS4777.2.

Product Ch