Infini 5.5KW with 2 enhanced MPP trackers and AC/solar charging current 60A. Automatic hybrid operation. The flexible and intelligent hybrid inverter can utilize solar power, AC utility and stored battery power without interrupting the power supply.
Description
Main Features:
- Pure sine wave output
- Self-consumption and Feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current suits different types of batteries
- Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
- Built-in timer for various mode of on/off operation
- Multiple communication for USB, RS-232, Modbus and SNMP
- Monitoring software for real-time status display and control
Model |
InfiniSolar E5.5KW |
Maximum PV Input Power |
6500W |
Rated Output Power |
5500W |
Maximum Charging Power |
2880W |
GRID-TIE OPERATION |
PV INPUT (DC) |
Nominal DC Voltage/Max. DC Voltage |
360 VDC/500 VDC |
Start-up Voltage/Initial Feeding Voltage |
116 VDC/ 150 VDC |
MPP Voltage Range |
120 VDC~450 VDC |
Number of MPP Trackers/Max. Input Current |
2/2x 13A |
GRID OUTPUT (AC) |
Nominal Output Voltage |
202/208/220/230/240 VAC |
Output Voltage Range |
184-264.5 VAC* |
Max. Output Current |
23.9A* |
Power Factor |
>0.99 |
EFFICIENCY |
Maximum Conversion Efficiency (DC/AC) |
96% |
European Efficiency@Vnominal |
95% |
OFF-GRID OPERATION |
AC INPUT |
AC start-up Voltage/Auto Restart Voltage |
120-140 VAC/180 VAC |
Acceptable Input Voltage Range |
170-280 VAC |
Max. AC Input Current |
40 A |
PV INPUT (DC) |
Max. DC Voltage |
500 VDC |
MPP Voltage Range |
120 VDC~450 VDC |
Number of MPP Trackers/Max. Input Current |
2/2x13A |
BATTERY Mode Output (AC) |
Nominal Output Voltage |
202/208/220/230/240 VAC |
Output Waveform |
Pure sinewave |
Efficiency (DC to AC) |
93% |
HYBRID OPERATION |
PV INPUT (DC) |
Nominal DC Voltage/Max. DC Voltage |
360 VDC/ 500 VDC |
Start-up Voltage/Initial Feeding Voltage |
116 VDC/ 150 VDC |
MPP Voltage Range |
120 VDC~450 VDC |
Number of MPP Trackers/Max. Input Current |
2/2x13A |
GRID OUTOUT (AC) |
Nominal Output Voltage |
202/208/220/230/240 VAC |
Output Voltage Range |
184-264.5 VAC* |
Max. Output Current |
23.9 A* |
AC INPUT |
AC Start-up Voltage/Auto Restart Voltage |
120-140 VAC/180 VAC |
Acceptable Input Voltage Range |
170-280 VAC |
Max. AC Input Current |
40 A |
BATTERY MODE OUTPUT (AC) |
Nominal Output Voltage |
202/208/220/230/240 VAC |
Efficiency (DC to AC) |
93% |
BATTERY& CHARGER |
Nominal DC Voltage |
48 VDC |
Max. Solar Charging Current |
60 A |
GENERAL |
PHYSICAL |
Dimension, D x W x H (mm) |
110 x 450 x 445 |
Net weight (kgs) |
16 |
INTERFACE |
External Safety Box (Optional) |
RS-232/USB |
Communication |
Optional SNMP, Modbus and AS-400 cards available |
ENVIRONMENT |
Humidity |
0~90% RH (Non-condensing) |
Operating Temperature |
0 to 40 °C |
Altitude |
0-1000 m** |